Skip to content
SWING INTO SPRING SALE! GET $$$ OFF ALL NATIONAL SAFETY APPAREL AND CHICAGO PROTECTIVE APPAREL ORDERS!
SWING INTO SPRING SALE! GET $$$ OFF ALL NATIONAL SAFETY APPAREL AND CHICAGO PROTECTIVE APPAREL ORDERS!

Country

MIRA NBC-17-SOF Gas Mask Filter 40mm NATO Thread CBRN | Free Shipping and No Sales Tax

Save 30% Save 30%
Original price $99.98
Original price $99.98 - Original price $99.98
Original price $99.98
Current price $69.97
$69.97 - $69.97
Current price $69.97

MIRA NBC-17-SOF Gas Mask Filter 40mm NATO CBRN. 

Available from MIRA at same price, but our “Special Offer” discount, No Sales Tax & Free Shipping is a real money saver. Buy Now while limited time offer is available. Worldwide MIRA distributor.

10 Year Shelf Life Safe and comfortable fit. Lighter weight and approx. 1 inch smaller in all directions than the NBC-77-SOF, and for less money!

It’s everything you love about the NBC-77 SOF filter—in a compact, TAPR-friendly package.  

Our NBC-17 is one of the smallest gas mask filters we offer, but it can still protect you from a broad spectrum of biological, chemical, and nuclear threats.

And will fit any respirator or PAPR that accepts standard NATO 40mm threads.

The NBC-17 SOF 40mm gas mask filter canister, in combination with a full-face mask, mouthpiece assembly, TAPR, or PAPR, reliably protects air passages against a wide range of harmful substances including CBRN agents.

The filters are produced with standard round threads according to STANAG 4155 (EN 148- 1)- Rd 40x1/7". The filter components are made of hard plastic. This results in a very robust product that is extremely durable against shock and impact damage in operational use.

NBC-17 SOF GAS MASK FILTER KEY FEATURES:

  • Compatible with standard 40mm NATO threaded respirators, which are widely available.
  • 10-year shelf life - save money long-term by not having to replace your filters every year.
  • Used by military personnel, CBRN specialists, and special operations forces all over the world
  • Rated for A2B1E1K1P3 D R.
  • Certified by European agencies and has the “CE” symbol. Compliant under EN 14387+A1

 

TECHNICAL DATA

BREATHING RESISTANCE IN PA BREATHING RESISTANCE IN PA

Diameter

90 mm

@ flow rate 30l/min. EN 1) NBC-17 SOF 260 <200

@ flow rate 95l/min. EN 1) NBC-17 SOF 980 <800

Height

85 mm

Weight

205 g ±5%

Storage time

10 years (factory sealed)

Type and Class Particle filter efficiency @ flow rate 95l/m

Particle filter efficiency @ flow rate 95l/m

A2 - organic gases and vapors

Sodium Chloride NaCl (S) Paraffin oil (L)

EN 99.95 99.95

NBC-17 SOF >99.999 >99.999

B1 - inorganic gases and vapors

P3 - particles

E1 - acid gases and vapors

D- dust

K1 - ammonia and amines

R- reusable

Note:
1) Standard EN 14387+A1
2) The filter was tested on dolomite dust clogging

NBC-17 SOF GAS MASK FILTER APPLICATION:

The filter provides reliable protection against solid and liquid aerosols, smoke-producing substances, radioactive particles, bacteria, viruses, vapors of organic and inorganic acids, hydroxides, organic solvents with a boiling point above 65°C, ammonia, amines, acid gases, agricultural chemical combustion products, tear-producing agents, irritants, choking agents, blister and nerve agents, (e.g., bromoacetone, CS substance, organic compounds of arsenic, phosgene, hydrogen cyanide, cyanogen chloride, mustard gas, organophosphates) – sarin, IVA, VX and other toxic substances, (e.g., benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, phosgene, phosphoric acid and its organic derivatives, chloroacetic acid, nitric acid, aldehydes, mixtures of inorganic acids and organic substances.)

 

TESTING GAS

CONCENTRATION OF TESTING GAS

BREAKTHROUGH TIME IN MINUTES EN

NBC-17 SOF

DAC IN GRAMS NBC-17 SOF

PPM

MG/I

A2

Cyclohexane

C₆H₁₂

5000

17.5

35

37

19.425

B1

Chlorine

Cl₂

1000

15

20

>30

>2.700

Hydrogen Sulphide

H₂S

1000

7.1

40

>60

>2.520

Hydrogen Cyanide

HCN

1000

5.6

25

>60

>5.820

E1

Sulphur Dioxide

SO₂

1000

13.3

20

>30

>2.430

K1

Ammonia

NH₃

1000

3.5

40

>60

>1.260



GAS MASK FILTER LIFETIME:

Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

GAS MASK FILTER STORAGE AND MAINTENANCE:

Each NBC-17 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

GAS MASK FILTER DISPOSAL:

After use, gas mask filters are considered special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.